Texture Series Laminated Metal

Creates a delicate and elegant finish on metal plates

The Textured series laminated metal features a detailed 3D texture, making it ideal for unique and outstanding decorative styles. The Brass Frieze laminated metal has an antique furniture-like metallic luster. The Beige Stripes laminated metal offers streamlined, three-dimensional textures that evoke a sense of modernity and contemporary elegance.

Laminated metal is crafted by combining PVC film with various metal sheets, offering superior fire resistance and easy maintenance.

A key advantage of using laminated metal as a decorative building material is its ability to utilize various materials and textures of PVC films to complement the metal sheets. This process delivers the inherent strength and toughness of metal, combined with a wide array of style options.

Product Application and Specification

Suggested Use:

  1. Interior Decoration and System Components:
  2. Wall Panels
  3. Door Panels
  4. Ceiling Panels and Grille/ Grid Ceilings Panels
  5. Office Partition Panels
  6. Elevator cabin Interiors
  7. Electronic equipment enclosures (computer cases, home appliances)
  8. Automotive Interiors

General Testing

ItemNameReference StandardTest Result
AppearanceGlossJIS K 5600, ASTM D523Pass
Color differenceCIE 1976 L*a*b* standard, ASTM E313See Sample
Adhesive property(100 squares method)JIS K 5600, ASTM D3359Pass
Workability TestLamination property(Erichsen test)JIS K 6744, JIS B 7729, LCM spec.Pass
Bending propertyJIS K 6744, ASTM D4145Pass
Low temperature processing propertyJIS K 6744Pass
Durability TestChemical resistanceJIS K 6744Pass
Stain resistanceJIS K 5600, CNS 423, CNS 11312, CNS 2984Pass
Boiling water resistanceLCM spec., JIS K 6744, ASTM D2485Pass
Abrasion resistanceASTM D4060Pass
Salt spray testJIS Z 2371, JIS K 8180,JIS Z8802Pass
Thermal cycling testLCM spec., JIS K 6744, ASTM D3359Pass

If the application uses for outdoor than you can review the page of our Outdoors Laminated Metal.

Fire Resistance Certificate

Complies with CNS 14705-1 test, class 2 fire resistance regulation.

CNS 14705-1 Fire-Resistance Test Standard
Applies constant heat power (50 kW/㎡) to a fixed-surface material
Fire Resistance
Classification / Criteria
Class 1Class 2Class 3
Heating Time (minutes)20105
Total Heat Release (MJ/㎡)≤ 8≤ 8≤ 8
Duration above 200 kW/㎡ (seconds)≤ 10≤ 10≤ 10
Presence of cracks or holes penetrating to the back that may compromise fire safetyNoneNoneNone
Recommended ApplicationsEmergency escape routes, stairwells, hazardous material storage or high fire-risk areasGeneral indoor spaces, rooms with heating equipment, high-rise buildings, basementsGeneral indoor areas

Images of Fire Resistance Certificates

Package Method

Lienchy Metal ships our products in coils or sheets, offering customer-assigned services to meet your expectations. For detailed information on our packaging, please refer to our Protective Film and Package section.

Packaging and shipping procedure of Lienchy Metal products